72.
A man exhales 0.002 m3 of CO2 per min when working in a confined space in underground. Assuming that the fresh air contains 0.03% CO2, the minimum quantity of fresh air to be supplied per person in m3/min, so that concentration of CO2, in air never crosses 0.4%, will be

74.
In a mine ventilation system, the resistances of two splits A and B are 0.5 Ns2m-8 and 2 Ns2m-8 respectively. Combined resistance of two shafts and trunk airways is 0.7 Ns2m-8. A quantity of 20 m3/s of air passes through split A. The total air power of the ventilation system in kW are

77.
In a longwall panel, the main gate road is 1000 m long, 4.5 m wide and 2 m high. The gate road is to be used for airflow at the rate of 17 m3/s. Considering a coefficient of resistance of airways of 0.01, the pressure in Pa required to maintain the airflow in the gate road is