A 6 hours storm had 4 cm of rainfall and the resulting runoff was 2 cm. If ϕ index remains at the same value, the runoff due to 10 cm of rainfall in 12 hours in the catchment is
A. 4.5 cm
B. 6.0 cm
C. 7.5 cm
D. 9.0 cm
Answer: Option B
Solution(By Examveda Team)
Infiltration Rate =2/6=1/3cm/hrInfiltration=1/3*12=4cm
Run-off= 10-4=6 cm
Join The Discussion
Comments ( 1 )
Related Questions on Irrigation Engineering
Finally formed berms in canals are provided for
A. Protection of banks erosion by the waves
B. Control of seepage losses
C. Strengthening of banks
D. All the above
Canals constructed for draining off water from water logged areas, are known
A. Drains
B. Inundation canals
C. Valley canals
D. Contour canals
A hydroelectric scheme operating under a head of 80 m will be classified as
A. low head scheme
B. medium head scheme
C. high head scheme
D. none of the above
A. Low sodium water
B. Medium sodium water
C. High sodium water
D. Very high sodium water
Pi index=( precipitation-Runoff) /time
=4-2/6
= 0.33cm/h
Runoff due to 10cm of rainfall= 10- 0.33*12
=10-3.9
=6.04 ie 6 cm