Examveda
Examveda

If the optimum depth of kor watering for a crop is 15.12 cm, the outlet factor for the crop for four week period in hectares per cumec, is

A. 1000

B. 1200

C. 1400

D. 1600

Answer: Option D


This Question Belongs to Civil Engineering >> Irrigation Engineering

Join The Discussion

Comments ( 5 )

  1. Rajnish Kumar
    Rajnish Kumar :
    3 years ago

    D=8.64B/D where B-Day ,∆-meter , 8.64×28÷0.1512=1600

  2. AMJID AFRIDI
    AMJID AFRIDI :
    6 years ago

    sorry, Delta= 8.64 B/D, also we can write D= 8.64 B/delta
    here we have delta in cm = 15.12/100= 0.1512
    Base period is given = 28 days
    D= 8.64 X 28 /0.1512 =1600

  3. AMJID AFRIDI
    AMJID AFRIDI :
    6 years ago

    delta =8.64 B/D
    =(8.84 x 28) / (15.12/100)

  4. AMJID AFRIDI
    AMJID AFRIDI :
    6 years ago

    delta =8.64 B/D
    =(8.84 x 28) / (15.12/100)

  5. AMJID AFRIDI
    AMJID AFRIDI :
    6 years ago

    delta =8.64 B/D
    =(8.84 x 28) / (15.12/100)