Examveda
Examveda

If a D.C. shunt motor is working at full load and if shunt field circuit suddenly opens

A. This will make armature to take heavy current, possibly burning it

B. This will result in excessive speed, possibly destroying armature due to excessive centrifugal stresses

C. Nothing will happen to motor

D. Motor will come to stop

Answer: Option A


This Question Belongs to Electrical Engineering >> D.C. Motors

Join The Discussion

Related Questions on D.C. Motors