ExamVeda
Login
Home
1
The condition for maximum efficiency for a D.C. generator is
Discuss
Answer & Solution
Answer: Option D
No explanation is given for this question. Let's Discuss on Board
2
If a D.C. motor is connected across the A.C. supply it will
Discuss
Answer & Solution
Answer: Option D
Solution:
If a D.C. motor is connected across an A.C. supply, it will burn due to the heat produced in the field winding by eddy currents.

The field windings in a D.C. motor are designed for direct current, and when subjected to alternating current, the changing magnetic fields induce eddy currents in the windings.

These eddy currents generate excessive heat, leading to potential damage or burning of the motor.
3
The speed of a D.C. shunt motor can be increased by
Discuss
Answer & Solution
Answer: Option B
No explanation is given for this question. Let's Discuss on Board
4
The armature voltage control of D.C. motor provides
Discuss
Answer & Solution
Answer: Option A
No explanation is given for this question. Let's Discuss on Board
5
Starters are used with D.C. motors because
Discuss
Answer & Solution
Answer: Option D
No explanation is given for this question. Let's Discuss on Board
6
If Ia be the armature current, then speed of a D.C. shunt motor is
Discuss
Answer & Solution
Answer: Option A
No explanation is given for this question. Let's Discuss on Board
7
In case of D.C. shunt motors the speed is dependent on back e.m.f. only because
Discuss
Answer & Solution
Answer: Option D
Solution:
In the case of D.C. shunt motors, the speed is dependent on back e.m.f. only because

Flux is practically constant in D.C. shunt motors.

In a shunt motor, the field winding is connected in parallel with the armature winding. This configuration ensures that the flux (magnetic field) remains relatively constant, regardless of changes in load or speed.

As a result, the back electromotive force (e.m.f.) generated in the armature is primarily determined by the speed of the motor and not significantly affected by changes in the flux.

Therefore, the correct option is Flux is practically constant in D.C. shunt motors.
8
A direct on line starter is used: for starting motors
Discuss
Answer & Solution
Answer: Option A
No explanation is given for this question. Let's Discuss on Board
9
The ratio of starting torque to full-load torque is least in case of
Discuss
Answer & Solution
Answer: Option B
No explanation is given for this question. Let's Discuss on Board
10
For starting a D.C. motor a starter is required because
Discuss
Answer & Solution
Answer: Option B
No explanation is given for this question. Let's Discuss on Board