The Rankine's constant for a mild steel column with both ends hinged is
A. $$\frac{1}{{750}}$$
B. $$\frac{1}{{1600}}$$
C. $$\frac{1}{{7500}}$$
D. $$\frac{1}{{9000}}$$
Answer: Option C
Solution(By Examveda Team)
We have defined the term Rankine constant in the previous section while deriving the alternate form of the Rankine formula. The Rankine constant denoted by 𝜶 was given asα=σc/π2E
This Rankine constant is different for various materials. The Rankine constant for some of the materials used in the construction of columns is given in the table below:
Materials | Rankine Constant (α) |
---|---|
Wrought Iron | 1/9000 |
Cast Iron | 1/1600 |
Mild Steel | 1/7500 |
Strong Timber | 1/750 |
Join The Discussion
Comments ( 1 )
Related Questions on Strength of Materials in ME
A. Equal to
B. Less than
C. Greater than
D. None of these
A. $$\frac{{{\text{w}}l}}{6}$$
B. $$\frac{{{\text{w}}l}}{3}$$
C. $${\text{w}}l$$
D. $$\frac{{2{\text{w}}l}}{3}$$
The columns whose slenderness ratio is less than 80, are known as
A. Short columns
B. Long columns
C. Weak columns
D. Medium columns
solution