The following system is not generally used
A. 1-phase 3-wire
B. 1-phase 4-wire
C. 3-phase 3-wire
D. 3-phase 4-wire
Answer: Option C
Solution(By Examveda Team)
Option A: 1-phase 3-wireThis represents a single-phase electrical system with three wires. It is commonly used for residential and small commercial applications where a split-phase system is required, providing two live conductors and one neutral conductor.
Option B: 1-phase 4-wire
This is another single-phase system, but it includes an additional ground wire (4 wires in total). It is commonly used for applications where a ground connection is necessary for safety, such as in residential distribution panels.
Option C: 3-phase 3-wire
This represents a three-phase electrical system with three wires and no neutral conductor. It is used in some industrial and commercial applications where a neutral conductor is not required, and balanced loads are expected across the three phases.
Option D: 3-phase 4-wire
This is a standard three-phase electrical system with four wires, including three live conductors and one neutral conductor. It is widely used for industrial and commercial applications, providing a neutral for unbalanced loads and additional safety.
The option that is not generally used in standard electrical distribution systems is Option C: 3-phase 3-wire. While this configuration may be used in some specific industrial applications, it is less common in comparison to the other options provided. Most three-phase systems include a neutral conductor (Option D) for flexibility and safety.
Therefore, Option C: 3-phase 3-wire is the system that is not generally used in common electrical distribution.
Join The Discussion
Comments ( 4 )
Related Questions on Transmission and Distribution
By which of the following a bus-bar is rated?
A. Current only
B. Current and voltage
C. Current, voltage and frequency
D. Current, voltage, frequency and short time current
A. Static condenser
B. Synchronous condenser
C. Tap changing transformer
D. Booster transformer
The frequency of voltage generated, in case of generators, can be increased by
A. Using reactors
B. Increasing the load
C. Adjusting the governor
D. Reducing the terminal voltage
In aluminium conductors, steel core is provided to
A. Compensate for skin effect
B. Neutralise proximity effect
C. Reduce line inductance
D. Increase the tensile strength
1-phase 4-wire are generally not used ,with the increase in the number of wire the cost will increase. It is not cost effective.
correst option is B:-1ph 4 wire
The answer is B Cause of 1 phase 3 wires system is generally used at Rural area in India..
I need more information regarding this question