Biochemical Oxygen Demand (B.O.D.) of safe drinking water must be
Discuss
Answer & Solution
Answer: Option A
Solution:
Biochemical Oxygen Demand (B.O.D.): Biochemical Oxygen Demand is a measure of the amount of oxygen that microorganisms will consume while decomposing organic matter in water. It is an important parameter for assessing water quality.

Safe Drinking Water: For water to be considered safe for drinking, it should have very low levels of organic matter and microbial contamination. Therefore, the B.O.D. of safe drinking water should be as close to zero as possible.

Explanation of Options:

Option A: nil - Indicates that there is no measurable oxygen demand, meaning the water is free from organic contaminants. This is the ideal and safest level for drinking water.

Option B: 5 - A B.O.D. level of 5 mg/L indicates some presence of organic matter, which is higher than acceptable for safe drinking water.

Option C: 10 - A B.O.D. level of 10 mg/L is too high for safe drinking water and indicates significant organic pollution.

Option D: 15 - A B.O.D. level of 15 mg/L is far too high and indicates severe contamination by organic matter.

Therefore, the Biochemical Oxygen Demand (B.O.D.) of safe drinking water must be nil.
22
For determining the velocity of flow of underground water, the most commonly used non-empirical formula is
Discuss
Answer & Solution
Answer: Option A
No explanation is given for this question. Let's Discuss on Board
23
Aeration of water is done to remove
Discuss
Answer & Solution
Answer: Option A
No explanation is given for this question. Let's Discuss on Board
24
Disinfection of drinking water, is done to remove
Discuss
Answer & Solution
Answer: Option B
No explanation is given for this question. Let's Discuss on Board
25
Specific capacity or yield of wells, is generally expressed, as
Discuss
Answer & Solution
Answer: Option D
Solution:
Specific capacity, also known as the yield of wells, is a measure of the efficiency and productivity of a well. It is typically expressed as the volume of water a well can produce per unit time per unit drawdown per unit area. The appropriate units for expressing specific capacity are m3/hour/m2/m, which represents cubic meters of water per hour per square meter of well area per meter of drawdown.

This unit of measurement helps in comparing the performance of different wells and in assessing their sustainability for water supply purposes.
26
The least thickness of class B cast iron (spun) pipe, is
Discuss
Answer & Solution
Answer: Option C
No explanation is given for this question. Let's Discuss on Board
27
The maximum depth of sedimentation tanks is limited to
Discuss
Answer & Solution
Answer: Option D
No explanation is given for this question. Let's Discuss on Board
28
Corrosion of well pipes may not be reduced by
Discuss
Answer & Solution
Answer: Option D
No explanation is given for this question. Let's Discuss on Board
29
Pick up the incorrect statement from the following. The underground sources of water, is from
Discuss
Answer & Solution
Answer: Option D
No explanation is given for this question. Let's Discuss on Board
30
Pick up the correct statement from the following:
Discuss
Answer & Solution
Answer: Option D
No explanation is given for this question. Let's Discuss on Board