A 200 mm thick wall made of modular bricks is 5 m long between cross walls and 3.8 m clear height between RCC slabs at top and bottom. The slenderness ratio of the wall is

Answer & Solution
Correct Answer: Option A
Let's discuss the solution. Join the discussion
Examveda
Question posted by Examveda
Community

Join the Discussion

3 Comments
CIVIL ENGINEERING
CIVIL ENGINEERING 5 years ago
h is to be modified as 3/4h = 3*3.8/4 = 2.85 for modular brick 🧱 now slenderness ratio =2.85/.19 = 15

@BabuAllrounder YouTube Channel
Muhammad Saqib
Muhammad Saqib 6 years ago
3.8/.2 =15
Sudipta Biswas
Sudipta Biswas 8 years ago
answer is 3.8*1000/200=19