A Roadheader district produces 20 mg/m3 of airborne dust with the following size distribution:
Size up to Cumulative wt%
1 μm 1
5 μm 5
10 μm 10
20μm 20
50μm 50
>50μm 100
The concentration of respirable fraction of dust in mg/m3 is

A. 0.2

B. 2.0

C. 10.0

D. 1.0

Answer: Option D