ExamVeda
Login
Home
71
What is the role of split spoon sampler in SPT?
Discuss
Answer & Solution
Answer: Option C
Solution:
The split spoon sampler is used in the SPT to collect disturbed samples of soil for identification and classification.
72
What type of soil is best identified through a vane shear test?
Discuss
Answer & Solution
Answer: Option B
Solution:
The vane shear test is most suitable for determining the undrained shear strength of soft to stiff cohesive clays.
73
Which boring method uses continuous flight helical screw?
Discuss
Answer & Solution
Answer: Option C
Solution:
Auger boring uses a helical screw that rotates and brings soil to the surface for sampling and inspection.
74
Which geophysical method is best suited for detecting groundwater tables?
Discuss
Answer & Solution
Answer: Option B
Solution:
The resistivity method is sensitive to changes in moisture content and is highly effective for locating groundwater tables.
75
What is a core barrel used for in geotechnical drilling?
Discuss
Answer & Solution
Answer: Option C
Solution:
A core barrel is a tool used during rotary drilling to recover cylindrical rock cores, useful for geological logging and testing.
76
What does a borehole log primarily document?
Discuss
Answer & Solution
Answer: Option B
Solution:
A borehole log provides a detailed record of the subsurface soil and rock layers, groundwater conditions, and sampling depths encountered during drilling. It's essential for engineering analysis.
77
Which method is used to obtain high-quality rock core samples?
Discuss
Answer & Solution
Answer: Option C
Solution:
Rotary core drilling involves rotating a hollow drill bit to cut and retrieve continuous cylindrical rock samples called cores.
78
What is the main advantage of using geophysical surveys in site investigations?
Discuss
Answer & Solution
Answer: Option C
Solution:
Geophysical methods like seismic or resistivity are non-destructive and cover large areas quickly, helping locate anomalies without excavation.
79
Which of the following provides the most accurate groundwater level measurement?
Discuss
Answer & Solution
Answer: Option C
Solution:
An observation well (or piezometer) allows direct and accurate measurement of groundwater level over time.
80
The Standard Penetration Test is carried out at intervals of:
Discuss
Answer & Solution
Answer: Option A
Solution:
The SPT is commonly performed at regular intervals of 1.5 meters or at changes in strata to evaluate soil consistency.