The time constant of a thermocouple is

A. The time taken to attain the final temperature to be measured

B. The time taken to attain 50% of the value of initial temperature difference

C. The time taken to attain 63.2% of the value of initial temperature difference

D. Determined by the time taken to reach 100°C from 0°C

Answer: Option C

Solution(By Examveda Team)

The Time Constant of a thermocouple is defined as the time required for the sensor to respond to 63.2% of its total output signal when subjected to a step change in temperature.

This Question Belongs to Mechanical Engineering >> Heat And Mass Transfer