A simply supported beam 6 m long and of effective depth 50 cm, carries a uniformly distributed load 2400 kg/m including its self weight. If the lever arm factor is 0.85 and permissible tensile stress of steel is 1400 kg/cm2, the area of steel required, is
A. 14 cm2
B. 15 cm2
C. 16 cm2
D. 17 cm2
Answer: Option C
Join The Discussion
Comments ( 1 )
Distribution of shear intensity over a rectangular section of a beam, follows:
A. A circular curve
B. A straight line
C. A parabolic curve
D. An elliptical curve
If the shear stress in a R.C.C. beam is
A. Equal or less than 5 kg/cm2, no shear reinforcement is provided
B. Greater than 4 kg/cm2, but less than 20 kg/cm2, shear reinforcement is provided
C. Greater than 20 kg/cm2, the size of the section is changed
D. All the above
In a pre-stressed member it is advisable to use
A. Low strength concrete only
B. High strength concrete only
C. Low strength concrete but high tensile steel
D. High strength concrete and high tensile steel
In a simply supported slab, alternate bars are curtailed at
A. $${\frac{1}{4}^{{\text{th}}}}$$ of the span
B. $${\frac{1}{5}^{{\text{th}}}}$$ of the span
C. $${\frac{1}{6}^{{\text{th}}}}$$ of the span
D. $${\frac{1}{7}^{{\text{th}}}}$$ of the span
tarq meo
Ast =M /sigma st x j x d.
= 10800000 /1400 x.85 x500.