31. If a cable of homogeneous insulation has a maximum stress of 10 kV/mm, then the dielectric strength of insulation should be A. 5 kV/mm B. 10 kV/mm C. 15 kV/mm D. 30 kV/mm Answer & Solution Discuss in Board Save for Later Answer & Solution Answer: Option B No explanation is given for this question Let's Discuss on Board
32. If the length of a cable is doubled, its capacitance A. Becomes one-fourth B. Becomes one-half C. Becomes double D. Remains unchanged Answer & Solution Discuss in Board Save for Later Answer & Solution Answer: Option C No explanation is given for this question Let's Discuss on Board
33. Cables for 220 kV lines are invariably A. Mica insulated B. Paper insulated C. Compressed oil or compressed gas insulated D. Rubber insulated Answer & Solution Discuss in Board Save for Later Answer & Solution Answer: Option C No explanation is given for this question Let's Discuss on Board
34. The metallic sheath may be made of lead or lead alloy or of aluminum. A. Yes B. No Answer & Solution Discuss in Board Save for Later Answer & Solution Answer: Option B No explanation is given for this question Let's Discuss on Board
35. The insulating material should have A. Low permittivity B. High resistivity C. High dielectric strength D. All of the above Answer & Solution Discuss in Board Save for Later Answer & Solution Answer: Option D No explanation is given for this question Let's Discuss on Board
36. The current carrying capacity of cables in D.C. is more than that in A.C. mainly due to A. Absence of harmonics B. Nonexistence of any stability limit C. Smaller dielectric loss D. Absence of ripples Answer & Solution Discuss in Board Save for Later Answer & Solution Answer: Option C No explanation is given for this question Let's Discuss on Board
37. Which of the following insulation is used in cables? A. Varnished cambric B. Rubber C. Paper D. Any of the above Answer & Solution Discuss in Board Save for Later Answer & Solution Answer: Option D No explanation is given for this question Let's Discuss on Board
38. It is difficult to maintain oil filled cables. A. Yes B. No Answer & Solution Discuss in Board Save for Later Answer & Solution Answer: Option A No explanation is given for this question Let's Discuss on Board
39. Is a cable is to be designed for use on 1000 kV, which insulation would you prefer ? A. Polyvinyle chloride B. Vulcanised rubber C. Impregnated paper D. Compressed SFe gas E. none of the above Answer & Solution Discuss in Board Save for Later Answer & Solution Answer: Option D No explanation is given for this question Let's Discuss on Board
40. The electrostatic stress in underground cables is A. Same at the conductor and the sheath B. Minimum at the conductor and maximum at the sheath C. Maximum at the conductor and minimum at the sheath D. Zero at the conductor as well as on the sheath Answer & Solution Discuss in Board Save for Later Answer & Solution Answer: Option C No explanation is given for this question Let's Discuss on Board