    Bcz mC is constant (93.33),so for permissible stress 140 N/mm^2(i.e.,Fe250)
    Xc=93.33/(93.33+140)=.399,so i.e.~0.40

Related Questions on Concrete Technology and Design of Concrete Structures

The diameter of ties in a column should be

A. More than or equal to one fourth of diameter of main bar

B. More than or equal to 5 mm

C. More than 5 mm but less than one-fourth of diameter of main bar

D. More than 5 mm and also more than one-fourth of diameter of main bar