1
The lowest thermal diffusivity is of
Discuss
Answer & Solution
Answer: Option D
Solution:
The lowest thermal diffusivity is of Rubber
2
The central air conditioning system has ___________ overall efficiency as compared to individual systems.
Discuss
Answer & Solution
Answer: Option C
Solution:

The central air conditioning system has Higher overall efficiency as compared to individual systems.
3
For air conditioning the operation theater in a hospital, the percentage of outside air in the air supplied is
Discuss
Answer & Solution
Answer: Option D
Solution:

For air conditioning the operation theater in a hospital, the percentage of outside air in the air supplied is 100
4
The vapour compression refrigerator employs the following cycle
Discuss
Answer & Solution
Answer: Option D
Solution:
The vapor compression refrigeration cycle employed by a typical refrigerator is a Reversed Rankine cycle. The Rankine cycle is commonly used in thermodynamic systems, especially in power plants, to convert heat energy into mechanical work. However, in a refrigeration system, the Rankine cycle is reversed to create a cooling effect.

The basic components of a vapor compression refrigeration system include a compressor, a condenser, an expansion valve, and an evaporator. Here's how the Reversed Rankine cycle works in a refrigerator:

1. Compression: The low-pressure, low-temperature vapor from the evaporator is compressed by the compressor, increasing its pressure and temperature.
2. Condensation: The high-pressure, high-temperature vapor is then condensed to a liquid in the condenser, releasing heat to the surroundings.
3. Expansion: The high-pressure liquid refrigerant passes through an expansion valve, where its pressure and temperature drop significantly, causing it to partially vaporize.
4. Evaporation: The low-pressure, low-temperature vapor-liquid mixture enters the evaporator, where it absorbs heat from the refrigerated space, cooling it down.

Option A: The Rankine cycle is a thermodynamic cycle used in power plants, not refrigeration systems.
Option B: The Carnot cycle is a theoretical thermodynamic cycle that represents the maximum possible efficiency of a heat engine or refrigerator, but it is not typically used in practical refrigeration systems.
Option D: The Reversed Carnot cycle is a conceptually similar cycle to the Reversed Rankine cycle, but the Rankine cycle is more commonly associated with vapor compression refrigeration.

Therefore, the correct answer is Option C: Reversed Rankine, as it represents the cycle employed by a vapor compression refrigerator to provide cooling.
5
The atmospheric air at dry bulb temperature of 15°C enters a heating coil maintained at 40°C. The air leaves the heating coil at 25°C. The bypass factor of the heating coil is
Discuss
Answer & Solution
Answer: Option C
Solution:

The atmospheric air at dry bulb temperature of 15°C enters a heating coil maintained at 40°C. The air leaves the heating coil at 25°C. The bypass factor of the heating coil is 0.6
6
During heating and humidification, the final relative humidity of air
Discuss
Answer & Solution
Answer: Option A
Solution:
During heating and humidification, the final relative humidity of air Can be lower or higher than that of the entering air
7
The thermostatic expansion valve is used in ________ type of evaporators.
Discuss
Answer & Solution
Answer: Option C
Solution:

The thermostatic expansion valve is used in Dry type of evaporators.
8
In a psychrometric process, the sensible heat added is 30 kJ/s and the latent heat added is 20 kJ/s. The sensible heat factor for the process will be
Discuss
Answer & Solution
Answer: Option B
Solution:
Sensible heat factor (s.h.f.) is the ratio of sensible heat to the total heat.
So,
$$\eqalign{ & {\text{s}}{\text{.h}}{\text{.f}}{\text{.}} = \frac{{30}}{{30 + 20}} \cr & = \frac{{30}}{{50}} \cr & = 0.6 \cr} $$
9
A pressure gauge on the discharge side of a refrigerant compressor reads too high. The reasons will be
Discuss
Answer & Solution
Answer: Option D
Solution:
A pressure gauge on the discharge side of a refrigerant compressor reads too high. The reasons will be
- Lack of cooling water
- Water temperature being high
- Dirty condenser surface
10
The change in evaporator temperature in a refrigeration cycle, as compared to change in condenser temperature, influences the value of C.O.P.
Discuss
Answer & Solution
Answer: Option A
Solution:
The change in evaporator temperature in a refrigeration cycle, as compared to change in condenser temperature, influences the value of C.O.P. more