ExamVeda
Login
Home
51
Tensile test can be performed on
Discuss
Answer & Solution
Answer: Option B
No explanation is given for this question. Let's Discuss on Board
52
Match the hardness test methods in Group 1 with the indentor used in Group 2.
Group 1 Group 2
P. Brinnel hardness 1. Brale indentor
Q. Vickers hardness 2. Square base diamond pyramid
R. Rockwell C hardness 3. 10 mm diameter steel ball
S. Rockwell B hardness 4. 1.6 mm diameter steel ball
Discuss
Answer & Solution
Answer: Option B
No explanation is given for this question. Let's Discuss on Board
53
Which of the following methods is not recommended for pre-cleaning prior to a liquid penetrant test
Discuss
Answer & Solution
Answer: Option D
No explanation is given for this question. Let's Discuss on Board
54
For a particular isotope, gamma radiation intensity is determined by
Discuss
Answer & Solution
Answer: Option C
No explanation is given for this question. Let's Discuss on Board
55
A property that can not be obtained from a tensile test is
Discuss
Answer & Solution
Answer: Option D
No explanation is given for this question. Let's Discuss on Board
56
The Brinell hardness measurement of a material is made by applying a 500 kg load with a 10 mm ball indentor. If the indentation diameter is 6 mm, the Brinell hardness (kg/mm2) will be
Discuss
Answer & Solution
Answer: Option A
No explanation is given for this question. Let's Discuss on Board
57
Brinell hardness measurement made with a 10 mm diameter steel ball at a load of 1000 kg gives an indentation of diameter 4 mm in a material. The BHN of this material is approximately
Discuss
Answer & Solution
Answer: Option D
No explanation is given for this question. Let's Discuss on Board
58
For HRM scale load and indenter are used
Discuss
Answer & Solution
Answer: Option B
No explanation is given for this question. Let's Discuss on Board
59
By X-ray diffraction, it is not possible to determine
Discuss
Answer & Solution
Answer: Option B
No explanation is given for this question. Let's Discuss on Board
60
Match the properties in Group 1 with the testing techniques in Group 2.
Group 1 Group 2
P. Electrical conductivity 1. Jominy test
Q. Impact energy 2. Izod test
R. Thermal expansion 3. Dilatometry
S. Specific heat 4. Four probe technique
5. Differential scanning calorimetry
Discuss
Answer & Solution
Answer: Option D
No explanation is given for this question. Let's Discuss on Board