ExamVeda
Login
Home
81
Which of the following are considered applications of ultrasonic testing?
Discuss
Answer & Solution
Answer: Option B
No explanation is given for this question. Let's Discuss on Board
82
Necking occurs in material at
Discuss
Answer & Solution
Answer: Option D
No explanation is given for this question. Let's Discuss on Board
83
Match the examination/inspection technique(s) in the following cases:
P. Internal crack developed in a component due to faulty metal flow conditions during its forging. 1. X-ray diffraction
Q. Segregation in steel casting. 2. Dye penetrant test
R. Hydride formation in a Tia Boy component due to its exposure to H2 at high temperature. 3. Sulphur printing
S. Surface cracks formed on a car body during its manufacture. 4. Radiography
Discuss
Answer & Solution
Answer: Option A
No explanation is given for this question. Let's Discuss on Board
84
When a longitudinal wave sound beam passes through an acoustic interface at some angle other than zero degrees
Discuss
Answer & Solution
Answer: Option C
No explanation is given for this question. Let's Discuss on Board
85
Hydrogen embrittled steels samples can exhibit
Discuss
Answer & Solution
Answer: Option D
No explanation is given for this question. Let's Discuss on Board
86
The ductile to brittle transition temperature of decreases by the addition of
Discuss
Answer & Solution
Answer: Option D
No explanation is given for this question. Let's Discuss on Board
87
The resolution of an optical microscope is of the order of
Discuss
Answer & Solution
Answer: Option B
No explanation is given for this question. Let's Discuss on Board
88
How is the wavelength of scattered radiation compared to the primary beam?
Discuss
Answer & Solution
Answer: Option A
No explanation is given for this question. Let's Discuss on Board
89
A 150 mm long cylinderical rod having a diameter of 100 mm contains six microvoids which are situated at radial distances of 5 mm, 8 mm, 12 mm. 20 mm, 30 mm, 36 mm respectively, on a given r-z plane. Along the length (z-direction) of the rod, the voids are spaced uniformly. The specimen is to be tested by an ultrasonic cylinderical probe, 7.5 mm in diameter: The maximum number of flows, that can be detected in a single measurement by placing the probe at one end of the rod (flat surface) is
Discuss
Answer & Solution
Answer: Option A
No explanation is given for this question. Let's Discuss on Board
90
Pyramid type diamond indenter is used in
Discuss
Answer & Solution
Answer: Option C
No explanation is given for this question. Let's Discuss on Board