ExamVeda
Login
Home
81
Inside the distillation columns, the
Discuss
Answer & Solution
Answer: Option D
Solution:
Option D: All of the above is the correct answer.

Option A: Highest temperature is near the feed plate
This is true because the feed plate is generally located between the rectifying and stripping sections. Since the bottom of the column is hotter (to vaporize the liquid) and the top is cooler (to condense vapors), the feed plate lies between these extremes and usually has a relatively high temperature, especially in comparison to the overhead.

Option B: Driving force for the liquid flow is its weight
This is correct. In a distillation column, the trays are arranged vertically, and gravity causes the liquid to flow from one tray to the next lower one through downcomers. Thus, the liquid flow is driven by its weight.

Option C: Vapors are not always at their dew points
Also true. Vapors in the column can be superheated or in equilibrium with liquid depending on the location and thermal gradients. Therefore, they are not necessarily always at their dew point.

Since all the individual statements are correct, the correct answer is: Option D: All of the above.
82
If moisture content of solid on dry basis is X, then the same on wet basis is
Discuss
Answer & Solution
Answer: Option A
No explanation is given for this question. Let's Discuss on Board
83
According to Poiseuille's law, the permeability for gas flow through a capillary is proportional to (where, $$\mu $$ = gas viscosity)
Discuss
Answer & Solution
Answer: Option B
No explanation is given for this question. Let's Discuss on Board
84
Air initially at 101. 3 kPa and 40°C and with a relative humidity of 50%, is cooled at constant pressure to 30°C. The cooled air has a
Discuss
Answer & Solution
Answer: Option C
No explanation is given for this question. Let's Discuss on Board
85
An aqueous solution of methanol is to be distilled in a tray column. High pressure steam is available as a source of heat. For a given reflux ratio and overhead composition, two options are being explored; (i) a reboiler is used and (ii) no reboiler is used but steam is fed directly to the bottom of the column. As compared to option (i), in option (ii)
Discuss
Answer & Solution
Answer: Option A
No explanation is given for this question. Let's Discuss on Board
86
The boiling points of pure components of a binary system __________ with increase in total pressure of the system.
Discuss
Answer & Solution
Answer: Option B
No explanation is given for this question. Let's Discuss on Board
87
Humid volume is the total volume in m3 of 1 kg of
Discuss
Answer & Solution
Answer: Option C
No explanation is given for this question. Let's Discuss on Board
88
The cooling effect in a cooling tower can not be increased by
Discuss
Answer & Solution
Answer: Option D
No explanation is given for this question. Let's Discuss on Board
89
The most efficient cooling tower out of the following is
Discuss
Answer & Solution
Answer: Option A
No explanation is given for this question. Let's Discuss on Board
90
Weight of 1 m3 of humid air as compared to 1 m3 of dry air, under the same conditions, is
Discuss
Answer & Solution
Answer: Option A
No explanation is given for this question. Let's Discuss on Board