ExamVeda
Login
Home
81
An aneroid barometer measures the __________ pressure.
Discuss
Answer & Solution
Answer: Option B
No explanation is given for this question. Let's Discuss on Board
82
Meleoid gauge measures the __________ pressure.
Discuss
Answer & Solution
Answer: Option B
No explanation is given for this question. Let's Discuss on Board
83
A manometer measures the __________ pressure.
Discuss
Answer & Solution
Answer: Option C
No explanation is given for this question. Let's Discuss on Board
84
Which of the following thermocouples is capable of measuring a temperature of -50°C?
Discuss
Answer & Solution
Answer: Option D
Solution:
1. Temperature Range of Each Thermocouple:
• Platinum–Platinum Rhodium (Type R or S) → Typically used for high temperatures, around 0°C to 1600°C. These thermocouples are designed for furnaces, metallurgy, and very high-temperature environments. Below 0°C, they become extremely insensitive and inaccurate.

• Chromel–Alumel (Type K) → Has a wide range of about −200°C to 1250°C, but its accuracy at low temperatures is poor. It becomes unstable and exhibits non-linearity below −50°C, so it is not preferred for precise low-temperature measurement.

• Iron–Constantan (Type J) → Range is around −40°C to 750°C. It cannot reliably measure below −40°C because iron begins to undergo changes (oxidation and magnetic effects). Measuring −50°C is already outside its optimal working range.

• Copper–Constantan (Type T) → Range is −200°C to +350°C. This thermocouple is specifically known for its excellent accuracy and stability at low temperatures. This makes it ideal for refrigeration, cryogenic applications, and any measurement involving temperatures below 0°C.

2. Why Copper–Constantan is Best for −50°C:
Copper–constantan provides:
• High sensitivity at low temperatures
• Very stable EMF output
• Minimal drift in the sub-zero range
• Accurate readings in the −50°C region

This is why industries such as food processing, environmental monitoring, and cryogenics commonly use Type T thermocouples for temperatures like −50°C.

3. Final Conclusion:
Only Copper–constantan (Type T) is specifically designed to measure −50°C accurately and reliably.

✔ Correct Answer: Option D – Copper–constantan
85
Which of the following is not a variable area flow meter?
Discuss
Answer & Solution
Answer: Option C
No explanation is given for this question. Let's Discuss on Board
86
Platinum resistance thermometer can be used upto antimony point which is __________ °C, and is the temperature of equilibrium between solid antimony & liquid antimony at normal atmospheric pressure.
Discuss
Answer & Solution
Answer: Option B
No explanation is given for this question. Let's Discuss on Board
87
Thermal conductivity cell is the primary element of a/an __________ analyser.
Discuss
Answer & Solution
Answer: Option B
No explanation is given for this question. Let's Discuss on Board
88
Magnetic flowmeters are generally not used for the velocity/flow measurement of hydrocarbons due to their
Discuss
Answer & Solution
Answer: Option B
No explanation is given for this question. Let's Discuss on Board
89
The transfer function of a process is $$\frac{1}{{16{{\text{s}}^2} + 8{\text{s}} + 4}}.$$    If a step change is introduced into the system, then the response will be
Discuss
Answer & Solution
Answer: Option A
No explanation is given for this question. Let's Discuss on Board
90
Which of the following thermocouples has the least temperature measurement range?
Discuss
Answer & Solution
Answer: Option A
No explanation is given for this question. Let's Discuss on Board