If the 20 mm rivets are used in lacing bars, then the minimum width of lacing bar should be

A. 40 mm

B. 60 mm

C. 80 mm

D. 100 mm

Answer: Option B


This Question Belongs to Civil Engineering >> Design Of Steel Structures

Join The Discussion

Comments ( 3 )

  1. Muhammad Saqib
    Muhammad Saqib :
    4 years ago

    Width of lacings=3 times dia of rivet

  2. Riju Das
    Riju Das :
    6 years ago

    *rivets

  3. Riju Das
    Riju Das :
    6 years ago

    Width of lacing bar =3*diameter of rive in (mm)