Examveda
Examveda

If the thickness of thinnest outside plate is 10 mm, then the maximum pitch of rivets in tension will be taken as

A. 120 mm

B. 160 mm

C. 200 mm

D. 300 mm

Answer: Option B


This Question Belongs to Civil Engineering >> Design Of Steel Structures

Join The Discussion

Comments ( 2 )

  1. Muhammad Saqib
    Muhammad Saqib :
    4 years ago

    Maximum pitch is 16t or 200mm which ever is less for tension and 12t or 200mm for compression,, so option B is correct if for tension

  2. Naveed Akhtar
    Naveed Akhtar :
    5 years ago

    Maximum pitch is 32 t or 300 mm in tension which ever is less