If the thickness of thinnest outside plate is 10 mm, then the maximum pitch of rivets in tension will be taken as

Answer & Solution
Correct Answer: Option B
Let's discuss the solution. Join the discussion
Examveda
Question posted by Examveda
Community

Join the Discussion

2 Comments
Muhammad Saqib
Muhammad Saqib 7 years ago
Maximum pitch is 16t or 200mm which ever is less for tension and 12t or 200mm for compression,, so option B is correct if for tension
Naveed Akhtar
Naveed Akhtar 7 years ago
Maximum pitch is 32 t or 300 mm in tension which ever is less