Fleming's right-hand rule regarding direction of induced e.m.f., correlates
Discuss
Answer & Solution
Answer: Option B
No explanation is given for this question. Let's Discuss on Board
42
Compensating windings are used in D.C. generators
Discuss
Answer & Solution
Answer: Option C
No explanation is given for this question. Let's Discuss on Board
43
Flashing the field of D.C. generator means
Discuss
Answer & Solution
Answer: Option B
No explanation is given for this question. Let's Discuss on Board
44
In a separately excited generator supplying rated load the armature reaction:
Discuss
Answer & Solution
Answer: Option A
No explanation is given for this question. Let's Discuss on Board
45
If a D.C. generator fails to build up the probable cause could not be
Discuss
Answer & Solution
Answer: Option B
No explanation is given for this question. Let's Discuss on Board
46
D.C. generators are connected to the bus-bars or disconnected from them only under the floating condition
Discuss
Answer & Solution
Answer: Option D
No explanation is given for this question. Let's Discuss on Board
47
Two generators are running in parallel. One of the generators may run as motor for which of the following reasons?
Discuss
Answer & Solution
Answer: Option D
No explanation is given for this question. Let's Discuss on Board
48
The function of pole shoes in the case of D.C. machine is
Discuss
Answer & Solution
Answer: Option D
No explanation is given for this question. Let's Discuss on Board
49
In case of a 4 pole D.C. generator provided with a two layer lap winding with sixteen coils, the pole pitch will be
Discuss
Answer & Solution
Answer: Option B
Solution:
Here's an explanation to help you understand the question:

First, let's define pole pitch. It is the distance between the center of two adjacent poles in a DC generator.

To calculate the pole pitch, we need to know the total number of slots or coil sides around the armature and the number of poles.

We are given:
* Number of poles (P) = 4
* Number of coils = 16
* Two layer winding means each coil has two coil sides.

Since it's a two-layer winding, the total number of coil sides is twice the number of coils: 16 coils * 2 coil sides/coil = 32 coil sides.

In a lap winding, the number of coil sides equals the number of armature conductors or slots. So, we have 32 slots.

The formula for pole pitch is:
Pole Pitch = (Total Number of Slots) / (Number of Poles)

So, Pole Pitch = 32 / 4 = 8

Therefore, the correct answer is Option B: 8.
50
For the parallel operation of two or more D.C. compound generators, we should ensure that
Discuss
Answer & Solution
Answer: Option D
No explanation is given for this question. Let's Discuss on Board