ExamVeda
Login
Home
91
The armature torque of the D.C. shunt motor is proportional to
Discuss
Answer & Solution
Answer: Option B
No explanation is given for this question. Let's Discuss on Board
92
What will happen if the back e.m.f. of a D.C. motor vanishes suddenly?
Discuss
Answer & Solution
Answer: Option C
No explanation is given for this question. Let's Discuss on Board
93
If a D.C. shunt motor is working at full load and if shunt field circuit suddenly opens
Discuss
Answer & Solution
Answer: Option A
No explanation is given for this question. Let's Discuss on Board
94
If a D.C. shunt motor is working at no load and if shunt field circuit suddenly opens
Discuss
Answer & Solution
Answer: Option C
No explanation is given for this question. Let's Discuss on Board
95
The main disadvantage of the Ward-Leonard control method is
Discuss
Answer & Solution
Answer: Option D
No explanation is given for this question. Let's Discuss on Board
96
D.C. series motors are used
Discuss
Answer & Solution
Answer: Option D
No explanation is given for this question. Let's Discuss on Board
97
Which one of the following is not necessarily the advantage of D.C. motors over A.C. motors?
Discuss
Answer & Solution
Answer: Option A
No explanation is given for this question. Let's Discuss on Board
98
Three point starter can be used for
Discuss
Answer & Solution
Answer: Option D
No explanation is given for this question. Let's Discuss on Board
99
These days D.C. motors are widely used in
Discuss
Answer & Solution
Answer: Option C
No explanation is given for this question. Let's Discuss on Board
100
In D.C. shunt motors as load is reduced
Discuss
Answer & Solution
Answer: Option C
Solution:
In a D.C. shunt motor, the field winding is connected in parallel (shunt) with the armature winding.

Since the field winding is connected directly across the supply, the field current remains nearly constant regardless of the load.

As a result, the magnetic field produced is stable, and any small change in armature current due to load variation has minimal effect on the speed.

Therefore, even when the load is reduced, the motor speed does not change significantly.

This is why D.C. shunt motors are widely used where constant speed is required.

Correct Answer: Option C