The use of higher flux density in the transformer design
Discuss
Answer & Solution
Answer: Option A
No explanation is given for this question. Let's Discuss on Board
62
A transformer has a 1:6 turns ratio and a secondary coil load resistance of 470 Ω. The load resistance as seen by the source is
Discuss
Answer & Solution
Answer: Option D
Solution:
Here's an explanation to help you understand how to solve this transformer question:

The question involves the concept of the turns ratio of a transformer and how it relates to the impedance transformation.

Turns Ratio (N1:N2): In this problem, the turns ratio is given as 1:6. This means for every 1 turn in the primary coil, there are 6 turns in the secondary coil. We can represent this as N1/N2 = 1/6.

Impedance Transformation: A transformer changes the apparent impedance (resistance in this case) seen by the source (primary side). The relationship is:

Z1 = (N1/N2)^2 * Z2

Where:
Z1 is the impedance seen by the source (primary side).
Z2 is the impedance of the load connected to the secondary side.
N1/N2 is the turns ratio.

In our problem:
N1/N2 = 1/6
Z2 = 470 Ω

Now, let's calculate Z1:
Z1 = (1/6)^2 * 470
Z1 = (1/36) * 470
Z1 ≈ 13.05 Ω

Therefore, the load resistance as seen by the source is approximately 13 Ω.

So the correct answer is Option D: 13 Ω
63
In a transformer the tappings are generally provided on
Discuss
Answer & Solution
Answer: Option D
Solution:
The correct answer is Option D: high voltage side.

Here's why:

When we put taps on the high voltage (HV) side of a transformer, it means that part of the winding has higher voltage but lower current for the same amount of power.
Because the current is lower on the HV side:
1. The wires needed for the tapping connections and the tap-changing switch (which moves between different tap points) can be thinner.
2. The switch itself (called a tap changer) can be much smaller, lighter, and less complex.
3. This makes the whole tap-changing mechanism significantly cheaper to build and maintain.

Now, let's look at why the other options are generally not preferred:
If taps were placed on the low voltage (LV) side (Option C), that side of the transformer carries a very high current.
1. Handling such high currents would require very thick wires for the tapping connections.
2. The tap-changing switch would need to be very robust, large, and heavy-duty to safely break and make connections carrying high current.
3. This would make the tap changer extremely expensive and bulky.

While Options A (primary side) and B (secondary side) can sometimes be the HV or LV side depending on whether the transformer is step-up or step-down, the general rule is to place taps where the current is lower to save cost and reduce complexity. This is almost always the high voltage side.
So, to keep the tap changer economical and practical, it's always placed on the side with lower current, which is the high voltage side.
64
No-load current in a transformer
Discuss
Answer & Solution
Answer: Option A
No explanation is given for this question. Let's Discuss on Board
65
The purpose of providing iron core in a step-up transformer is
Discuss
Answer & Solution
Answer: Option C
No explanation is given for this question. Let's Discuss on Board
66
Which of the following is not the standard voltage for power supply in India?
Discuss
Answer & Solution
Answer: Option D
No explanation is given for this question. Let's Discuss on Board
67
When the equivalent circuit diagram of doouble squirrelcage induction motor is constructed the two cages can be considered
Discuss
Answer & Solution
Answer: Option B
No explanation is given for this question. Let's Discuss on Board
68
An ideal transformer has infinite values of primary and secondary inductances. The statement is
Discuss
Answer & Solution
Answer: Option B
No explanation is given for this question. Let's Discuss on Board
69
During open circuit test of a transformer
Discuss
Answer & Solution
Answer: Option A
No explanation is given for this question. Let's Discuss on Board
70
Which of the following is not a routine test on transformers?
Discuss
Answer & Solution
Answer: Option C
No explanation is given for this question. Let's Discuss on Board